Part Number Hot Search : 
1N5774F 2SC3416 Z8420AD2 MM74HC00 1SS245 TC115 ZC830ATA 25025
Product Description
Full Text Search
 

To Download TRXQ1-433F Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 FM NARROW BAND TRANSCEIVERS
* * * * * * * * * *
RF Transceiver or Intelligent Modem Versions Host Data Rate upto 19,200 Baud Data Rates to 20 K baud. 2 Selectable RF Channels Narrowband Crystal Controlled Optimal Range 200m Supply Voltage 3-5V Very Stable Operating Frequency Low Profile Ceramic DIL Package Operates from -20 to +850C
TRXQ1 RXQ1
RXQ1 Version
* * * * *
RF Transceiver Version Only
TRXQ1 Version
Transceiver With RF600T Incorporated Serial Data Interface with Handshake Selectable Dumb or Intelligent Modem Modes On Board 190 Byte Buffer
Applications
* * * * *
Wireless Security Systems EPOS Terminals Sensor Data logging Remote Telemetry & Telecommand Remote Meter Reading
Description
The RXQ1 / TRXQ1 radio transceiver modules provide reliable wireless communications for the transfer of data at rates of up to 20 K baud. Their unique features of narrow band operation and user channel selection combined with excellent interference rejection make them an ideal choice for next generation applications. Operating within the 433.92MHz band the modules can operate in two narrow band channels; 433.92 MHz and 434.33MHz. The modules use a crystal controlled design which provides narrow band performance which is far superior to other wideband `SAW' based designs. The TRXQ1 Smart Radio Transceiver has the functions of a complete radio modem, it simply requires CMOS/TTL data at the transmit input and the corresponding transceiver(s) output the same data There RXQ1 provides a basic Radio transceiver. Possible applications include one-to-one and multi-node wireless links in applications including car and building security, EPOS, inventory tracking, remote industrial process monitoring and computer networking. Because of their small size and low power requirements, both modules are ideal for use in portable, batterypowered applications such as hand-held terminals.
Part Numbering
Part Number Description
TRXQ1-433F FM-RXQ1-433 RF600T-EVAL
Smart Transceiver Module 433MHz Transceiver Module 433MHz Evaluation Kit for Smart Radio Modules
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 1
FM NARROW BAND TRANSCEIVERS
RXQ1 Pinout Detail
Top View RF Gnd. 1 Antenna 2 RF Gnd. 3 nc 4 Gnd. 5 nc 6 nc 7 nc 8 Gnd. 9 RXQ1 FM Transceiver 18 Channel Select 17 Vcc 16 Rx Select 22.86 15 Tx Select 14 Tx Data 13 nc 12 Rx Data 11 nc 10 Gnd.
TRXQ1 RXQ1
30.48
Pin Descriptions
Pin Number Name Type Description
1,3 2 4, 6, 7, 8, 11, 13 5, 9, 10 12
RF GND Antenna nc GND Rx
In In / Out In Out
For best results, these pins should be connected to the ground plane against which the antenna radiates. Nominal 50 ohm input/output impedance capacitively isolated from the internal circuit. No Connection Connect to 0 volts. Received data output to host controller (CMOS logic out) representing true data as supplied to the transmitter. Transmit data input from host controller Data input to the transmitter can be directly interfaced to CMOS logic drive operating on the same supply voltage as the transceiver Transmit select. Active LOW. Receive select. Active LOW. Positive supply voltage connection. Decouple with 100n ceramic capacitor to ground. Channel Select; Logic 0 selects 433.92MHz Logic 1 selects 434.33MHz
14 15 16 17 18
Tx Tx SELECT Rx SELECT Vcc CS
In In In In In
Operation Table
Tx Select 0 0 1 1 RX Select 0 1 0 1 Function Power Down Mode Transmit Mode Receive Mode Power Down Mode
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
7
Page 2
FM NARROW BAND TRANSCEIVERS
RXQ1 Operating Parameters Absolute Maximum Ratings
Operating temperature: Storage temperature: Supply Voltage Data input -20 0 C to +70 0 C -40 0 C to +100 0 C -0.3 to 6V -0.3 to Vcc + 0.3v
TRXQ1 RXQ1
Electrical Characteristics:
Min. DC Levels Supply voltage Supply current (Transmit Mode) Supply current (Receive Mode) Supply current (Standby Mode) Data input/output high Data input/output low RF Working Frequency Receiver sensitivity RF power out (transmitter) FM Deviation IF Bandwidth Harmonic Spurious Emissions Operating Temperature Dynamic Timing Power up to stable receiver data out Power up to full RF out Standby to RX mode Standby to TX mode Changing from TX to RX mode Changing from RX to TX mode Data Bit rate 433.92 / 434.33 -100 5 +/- 15 65 -50 -20 +70 85 MHz dBm dBm KHz KHz dBc Deg C Into 50 2.7 Typ. 3 26 12 8 Max. 5.25 Units V mA mA uA V V Notes 1
0.7xVcc 0
Vcc 0.3xVcc
5 4 3 2 3 1 20 20,000
mS mS mS mS mS mS bps
2 2
Notes 1. Supply voltage should have <10mV ripple.
RXQ1 Applications
The RXQ1 is a dual band `transceiver only' RF module, which has applications in many areas where reliable half duplex communications are required over ranges up to 200 metres. The crystal controlled narrow band design gives optimum performance in the 433 MHz band and the dual channel capability allows for the design of more complex networks than had previously been possible.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 3
FM NARROW BAND TRANSCEIVERS
RXQ1 Application Information with RF600T
TRXQ1 RXQ1
The circuit below shows a typical application of the RXQ1 in conjunction with the RF600T low power radio transceiver controller. A 9 way `D' connector provides an RS232 termination to the host system and the RXQ1 hybrid contains all of the circuitry required to implement the RF path. The RF600T operates as a transceiver controller and performs all of the functions necessary to implement either a `dumb' or an intelligent modem with automatic retry and proof of deliver functions built in to the system. In many applications it will be possible to dispense with the option links and hard-wire options to their desired settings but note however option selection must be carried out exactly as described in the RF600T data sheet. This implementation of TRXQ1 module and RF600T is available as the composite hybrid TRXQ1 which is described in this data sheet.
2K2
2K2
2K2
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 4
FM NARROW BAND TRANSCEIVERS
TRXQ1 Pinout Detail
Top View RF Gnd. 1 Antenna 2 Channel Select 3 IN #1 4 IN #2 5 OUT #1 6 OUT #2 7 LRN/LED 8 \CTS 9 TRXQ1 Intelligent FM Transceiver 30.48 7 18 Vcc RF 17 Dig. Gnd. 16 RF Baud 22.86 15 Host Baud 14 Rx Data 13 TX Data 12 Mode 11 \RTS 10 Vcc Digital
TRXQ1 RXQ1
Pin Descriptions
Pin Number Name Type Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
RF GND Antenna CS IN #1 IN #2 OUT #1 OUT #2 LRN/LED \CTS (loop) Dig Vcc \RTS MODE TxData RxData Host Baud
Power In / Out In In In Out Out In/Out Out Power In In In Out In
16 17 18
RF Baud GND VccRF
In Power Power
For best results, this pin should be connected to the ground plane against which the antenna radiates. Nominal 50 ohm input/output impedance capacitively isolated from the internal circuit. Channel select option. Logic 0 selects 433.92MHz Logic 1 selects 434.33MHz Logic input #1 Logic input #2 Logic output #1 Logic output #2 Learn switch and status LED. Logic `0' is Clear To Send. Connect to 0 volts via 2.2K to enable loop mode. Positive supply voltage connection. Logic `0' is Request To Send. Mode select option. Logic `1' or open selects addressed mode. Logic `0' selects broadcast mode. Serial async. data input from the host. Serial async. data output to the host. Host baud rate selection option. Logic `1' or open selects 9600 bauds. Logic `0' selects 19200 bauds. RF baud rate (element time) select option. Logic `1' or open selects 400 us element time. Logic `0' selects 200 us element time. 0 volts. RF supply voltage connection. Level to be as Vcc Digital on pin 10 Decouple with a 100n capacitor close to the module supply pins.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 5
FM NARROW BAND TRANSCEIVERS
TRXQ1 Operating Parameters Absolute Maximum Ratings
Operating temperature: Storage temperature: Supply Voltage Data input Maximum output current -20 0 C to +70 0 C -40 0 C to +100 0 C -0.3 to 6V -0.3 to Vcc + 0.3v +/- 25 mA
TRXQ1 RXQ1
Electrical Characteristics:
Min. DC Levels Supply voltage Supply current (Transmit Mode) Supply current (Receive Mode) Data input/output high Data input/output low Output Pin Current rating LED sink current RF Working Frequency Receiver sensitivity RF power out (transmitter) FM Deviation IF Bandwidth Harmonic Spurious Emissions Operating Temperature Notes 1. Supply voltage should have <10mV ripple. 433.92 / 433.33 -100 5 +/- 15 65 -50 -20 +70 85 MHz dBm dBm KHz KHz dBc Deg C Into 50 3.0 Typ. 5.0 28 14 Max. 5.25 Units V mA mA V V mA mA Notes 1
0.7xVcc 0 5.0
Vcc 0.3xVcc 25 25
TRXQ1 Design Data
The TRXQ1 is an intelligent dual band communications module consisting of the RXQ1 transceiver circuitry and an RF600T embedded controller IC. Designers should study the RF600T data sheet (DS601) since this contains detailed information on the operation of this device. The design information given below should be read in conjunction with this data sheet.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 6
FM NARROW BAND TRANSCEIVERS
TRXQ1 Operating Modes
TRXQ1 RXQ1
The device is capable of operation in one of two modes, either broadcast or addressed. The following description describes the features of these mode and assumes two TRXQ1 nodes `A' and `B'. The RF600T must be configured before power up for either the broadcast or addressed mode of operation by means of the MODE pin. Note that for security, broadcast nodes will not receive data from addressed nodes Broadcast mode. This mode allows a host generated data block from node `A' to be transmitted and received by any number of other nodes. This data is received and verified (for correct Manchester coding and CRC) by the other nodes before being output to their host devices. Alternately, in the same way the other nodes can send data to node `A'. Note that although any node can initiate a transfer, only one direction of transfer can be active at a given time. Correct reception of a data packet is not acknowledged and the node hosts have the responsibility of ensuring that data transfers occur as required by operating some form of message protocol over the half duplex data link. Addressed mode This mode allows a host generated data block from node `A' to be transmitted and for the data frame to be addressed to one other network node - in this case we assume node `B'. When the data is received by node `B' it is verified for correct Manchester coding, CRC and for address match and then an acknowledge message is transmitted back to node `A'. Node `A' then outputs a confirmation to the host in the form of the ASCII character `C' (Confirmed). Note that confirmation is given when the data block is stored in the buffer of node `B' and not when it has been delivered to the host at node `B'. All message transfers are tagged with the addresses of both the origin and destination, thus ensuring secure data transfer at all times. Either node `A' or node `B' can initiate a transfer but only one direction of transfer can be active at a given time. In the event that the originating node does not get confirmation of receipt of the data packet, the software re-tries the transfer five times after which node `A' will output an error message to the host in the form of the ASCII character `F' (Failed). Correct reception (or otherwise) of a data packet is thus acknowledged and the host devices are relieved of most of the workload of ensuring that data transfers occur as required. The RF600T must be configured before use for either the broadcast or addressed point to point mode of operation and details of how this is carried out are given in the following section. System Operation Each RF600T is programmed at manufacture with a 24 bit serial number which uniquely identifies the device. In an addressed point to point system, these serial numbers are used as the device address for the nodes in the system and non-volatile eeprom memory in the device stores the address of the `other' node in the system. If, as at time of manufacture, no address has been stored in the device or if the address has been erased then the device will only operate in the broadcast mode. If however an address has been stored then the device will also be able to operate in the addressed point to point mode.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 7
FM NARROW BAND TRANSCEIVERS
TRXQ1 RXQ1
If operation in the broadcast mode is required then with a new device, no action is necessary. If a device has been used in the point to point addressed mode or if its status is unknown then status erase must be carried out using the following procedure. The LEARN pin is grounded for a period of 5 seconds and is then allowed to float, please note the unit must be in addressed mode in order to do this. The status LED then flashes slowly for 3 seconds to indicate that the device is erased and will now only operate in the broadcast mode until the learn sequence is repeated. If operation in the addressed mode is required then the following procedure has to be followed to allow the two nodes in the system to operate together. The option for addressed mode is selected. The two nodes, `A' and `B' are placed within radio range of one another are powered up. The LEARN pin on one device - say `B' is briefly taken low, placing the node into learn mode. The LEARN/ERASE status LED on `B' comes on and remains on for 20 seconds. If within this period, no `learn' data packet is received (see below) then the LED will be extinguished and the device will operate normally. At node `A', the LEARN pin is briefly taken low. The LEARN/ERASE status LED will then come on and node `A' will transmit its address. Node `B' will receive and store the address of 'A'. Node `B' sends back to node `A' both its address and that of node `A'. Node `A' receives and stores the address of 'B' and confirms to `B' that it has received the its address. Both node `A' and `B' LED's flash their its status LED's rapidly for 3 seconds to show that they have learned each others addresses. Addressed mode can then be entered by setting the mode selection pin on the chip as described in the PIN Descriptions table on page 5. (other nodes which may be active will ignore this transfer since they have not been placed in the learn mode) LRN/LED pin (addressed mode only) The learn/LED pin is used both to sense the learn/erase switch and also to drive the indicator LED and should be connected as shown in the RXQ1 application circuit. The switch, which should be of the normally open type, should be connected from the learn pin to ground. The LED and its series current limiting resistor should be connected from Vcc to the learn pin, ensuring that the maximum current drawn by the LED (as given in this data sheet) is not exceeded.
TRXQ1 Loop Mode
Loop mode is provided to allow testing of the performance of a system and allows node `A' to transmit a data packet which will be looped back by node `B' and received by node `A'. The mode settings of the nodes are ignored in the loop mode and the transfer is carried out in broadcast mode. The mode must only be selected when there are just two nodes in a network. If we assume that we wish to send a host data packet from node `A' to node `B' and have the packet returned such that host `A' receives back its data packet then the LOOP link in node `A' should be made before that unit is powered up. This unit will now only operate in the loop mode until it is powered down, the loop link removed and then powered up again.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 8
FM NARROW BAND TRANSCEIVERS
TRXQ1 application schematic: RS232 connection to host PC.
TRXQ1 RXQ1
Connection of the TRXQ1 to an RS232 host terminal device such as a PC serial port can be simply carried out using the circuit shown below. The 9 way `D' socket (CON1) provides the standard pinout required to connect directly to the serial port of any PC using a 9 way male/female cable. The MAX222 provides level conversion between the RS232 levels on the serial port and the logic levels pins of the TRXQ1 module. (note that direct connection of RS232 levels to the module will result in immediate destruction of the device) The TRXQ1 hybrid requires the following 4 signal connections to operate correctly: Tx Data: Rx Data: \CTS: \RTS: this is serial data which is to be transmitted by the hybrid. this is serial data which has been received by the hybrid. this control output to the host is low when it is Clear To Send data to the hybrid. this control input from the host is low when it is making a Request To Send data from the hybrid.
In this circuit, option selection is as follows: RF Baud rate (pin 16): Host Baud Rate (pin 15): Mode (pin 12): this pin is pulled high via a 22K resistor which selects 9600 bauds. this pin is pulled high via a 22K resistor which 400 us element time. this pin is pulled high via a 22K resistor which addressed mode.
If two such circuits are constructed then it will be possible to interconnect two PC's and test out the performance of the hybrids. When both circuits are powered up is will be necessary for them to learn one another's identity as described fully in the RF600T data sheet (DS601). That is - press the learn switch in one circuit, then in the other and the two learn LED's should flash showing that the learn has taken place. The addressed mode operates as a point to point half duplex system with automatic retry and indication to the transmitting host of the status of the transfer. Again the RF600T data sheet gives full information on this mode of operation. NOTE: pins 16, 15, 12 should not be left floating as these control important features of the TRXQ1 such as the baud rate and Mode of operation. Ensure that these pins are pulled either high with a ~22K resistor or pulled low with a ~2K2 resistor.
DS0353-9 March `05 (c)2005 Reg. No. 227 4001, ENGLAND Page 9
FM NARROW BAND TRANSCEIVERS
TRXQ1 RXQ1
TRXQ1 application schematic: logic level connection to host micro controller.
Direct connection of the TRXQ1 to a host micro controller allows the design of complex systems where the host micro controller provides all of the processing power and the TRXQ1 acts as the data carried between system nodes. The use of the broadcast mode will allow multiple transceiver systems to be implemented and with suitable software and a user defined protocol is will be possible to implement complex networks where control of the data path, retries etc. are under the control of the designer. Where a point to point system is required then the addressed mode will provide this and also give the required level of security. This, along with the automatic retry feature of the TRXQ1 module will remove from the system designer all of the normal overhead of writing communications software. As was the case with the RS232 example given above, the TRXQ1 hybrid requires 4 signal connections to operate correctly. TxHOST: RxHOST: \CTS: \RTS: serial data which is to be transmitted by the hybrid. serial data which has been received by the hybrid. control output to the host is low when it is Clear To Send data to the hybrid. control input from the host is low when it is making a Request To Send data from the hybrid.
In some addressed mode applications the learn/erase components may not be required and the LRN/LED pin could be connected to the host micro controller which would be programmed to handle the functions of this pin. Where the module is to be used in the broadcast mode then the learn/erase components will not be required which will lead to further simplification of the circuit.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 10
FM NARROW BAND TRANSCEIVERS
Antenna Design
TRXQ1 RXQ1
The design and positioning of the aerial is as crucial as the module performance itself in achieving a good wireless system range. The following will assist the designer in maximising system performance. The RF ground pin should be connected to a ground plane which should shield the aerial connection and the PCB layout around the aerial track itself should be such as to give a 50 Ohm impedance. The aerial should be kept as far away from sources of electrical interference as physically possible. The specified power supply decoupling capacitors should be placed close to the module as possible and have direct connections to the relevant pins. The antenna `hot end' should be kept clear of any objects, especially any metal as this can severely restrict the efficiency of the antenna to receive power. Earth planes restricting the radiation path of the antenna will also have the same effect. The best range will be achieved with either a straight piece of wire, rod or PCB track @ 1/4 wavelength (15.5cm @ 433.92MHz). Increased range may be achieved if this 1/4 wave antenna is placed perpendicular to and in the middle of a solid earth plane measuring at least 16cm radius. In this case, the antenna should be connected to the module using 50 Ohm coaxial cable and the PCB track layout tips given above should be observed.
Helical Antenna
RF RF 15.5cm @ 433MHz 34mm @ 433MHz 17 turns equally spaced = 5mm (inside)
Whip Antenna
Smart Radio Evaluation Kit (Please see Datasheet DS605)
The Smart Radio Evaluation Kit provides a hardware platform to enable fast development of Radio applications. Supplied as a pair of boards, each can accept a variety of RF Modules including transmitters, receivers and transceivers, an RS232 port is incorporated for direct connection to a PC. The boards may be used for a wide range of tasks from simple RS232 data transmission to integrated system development and is the ideal platform for exploring the advantages of using the "Smart Comms" range of ICs and radio modules. This eliminates the need to construct hand-wired prototype boards, which are rarely successful in creating a valid environment for the development of radio systems. (prototyping board also contains large stray capacitance values which has a detrimental effect on the RF connections).
* * * * * * * * *
Hardware Platform for Radio Comms Development Accepts Various RF Modules RS232 Interface to PC Supplied with RF600T Smart Comms Controller Performs all Data Encryption for Reliable Data Comms. Two Telemetry I/O Lines (addressed mode only) Range Testing Target Environment Testing Antenna Evaluation
Contents
* * * *
Two Eval Boards Two RF600T Comms Controllers Circuit diagrams Two RS232 PC cables
Radio Modules and Antenna available Separately.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 11
FM NARROW BAND TRANSCEIVERS
Mechanical Detail
TRXQ1 RXQ1
RF Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL. England Tel +44 (0)1273 898 000 Email sales@rfsolutions.co.uk Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association All Trademarks acknowledged and remain the property of the respected owners
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS0353-9 March `05
(c)2005 Reg. No. 227 4001, ENGLAND
Page 12


▲Up To Search▲   

 
Price & Availability of TRXQ1-433F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X